Repository of Research and Investigative Information

Repository of Research and Investigative Information

Zabol University of Medical Sciences

Characteristics and assessing biological risks of airborne bacteria in waste sorting plant

(2022) Characteristics and assessing biological risks of airborne bacteria in waste sorting plant. Ecotoxicology and Environmental Safety. p. 12. ISSN 0147-6513

Full text not available from this repository.

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

Examining the concentration and types of airborne bacteria in waste paper and cardboard sorting plants (WPCSP) is an urgent matter to inform policy makers about the health impacts on exposed workers. Herein, we collected 20 samples at 9 points of a WPCSP every 6 winter days, and found that the most abundant airborne bacteria were positively and negatively correlated to relative humidity and temperature, respectively. The most abundant airborne bacteria (in units of CFU m(-3)) were: Staphylococcus sp. (72.4) > Micrococcus sp. (52.2) > Bacillus sp. (30.3) > Enterococcus sp. (24.0) > Serratia marcescens (20.1) > E. coli (19.1) > Pseudomonas sp. (16.0) > Nocardia sp. (1.9). The lifetime average daily dose (LADD) for the inhalation and dermal routes for the intake of airborne bacteria ranged from 3.7 x 10(-3) <= LADD(Inhalation) <= 2.07 x 10(1) CFU (kg d)(-1) and 4.75 x 10(-6 )<= LADD(Dermal )<= 1.64 x 10(-5) CFU (kg d)(-1) , respectively. Based on a sensitivity analysis (SA), the concentration of airborne bacteria (C) and the exposure duration (ED) had the most effect on the LADD(Inhalation) and LADD(Dermal) for all sampling locations. Although the Hazard Quotient of airborne bacteria was HQ < 1, an acceptable level, the indoor/outdoor ratio (1.5 <= I/O <= 6.6) of airborne bacteria typically exceeded the threshold value (I/O > 2), indicating worker's exposure to an infected environment. Therefore, in the absence of sufficient natural ventilation the indoor ambient conditions of the WPCSP studied should be controlled by supplying mechanical ventilation.

Item Type: Article
Keywords: Health risk assessment Airborne bacteria Hazard quotient Paper and cardboard Indoor/outdoor bacteria municipal solid-waste occupational-exposure microbial diversity bioaerosols fungi emissions aerosol workers Environmental Sciences & Ecology Toxicology
Divisions:
Page Range: p. 12
Journal or Publication Title: Ecotoxicology and Environmental Safety
Volume: 232
Identification Number: 10.1016/j.ecoenv.2022.113272
ISSN: 0147-6513
Depositing User: مهندس مهدی شریفی
URI: http://eprints.zbmu.ac.ir/id/eprint/4238

Actions (login required)

View Item View Item